Short answer: Starting a Georgia clinical lab today means choosing the right CLIA certificate (there is no state license step), designing workflow and budget, building a quality management system with QC, IQCP, PT, and competency, validating methods, and rehearsing the survey with a mock inspection. Sound Lab Consultants delivers each step.
Startup, QMS, validation, and mock inspections
- Test menu and complexity decision; CLIA certificate type
- Layout and specimen workflow; budget; LIS selection
- QMS: document control, QC, IQCP, PT, competency, quality assessment
- Method verification (FDA-cleared) and validation (LDTs/modified tests)
- Mock inspection against CLIA, CAP, or COLA checklists with a written report
- CMS-2567 plan of correction support
CLIA leadership roles
| Role | 42 CFR 493 | Needed for |
|---|
| Laboratory director | 493.1405 / 493.1443 | Moderate / high complexity |
| Technical consultant | 493.1411 | Moderate complexity |
| Technical supervisor | 493.1449 | High complexity |
| General supervisor | 493.1461 | High complexity |
Directors must be on site at least every 6 months (at least 4 months apart) and may direct no more than five labs. Full hiring guide with BLS pay data: hire a lab director or lab manager in Georgia.
Georgia rules that apply to clinical labs today
- No state clinical lab license since July 1, 2021. House Bill 93 (Act 223) removed state licensure for clinical laboratories, collection stations, tissue banks, and laboratory directors and ended state lab inspections; DCH suspended enforcement of the old Rule 111-8-10 (DCH notice). Labs may choose to keep following those rules voluntarily.
- Federal CLIA still applies. The DCH Healthcare Facility Regulation Division (HFRD), Diagnostic Services is Georgia's CLIA state agency. Email the CMS-116 to HFRD.Diagnostic@dch.ga.gov and allow 30–45 business days.
- Notifiable disease reporting. O.C.G.A. § 31-12-2 and Rule 511-2-1-.02 require labs to report through SendSS or other DPH methods; electronic lab reporting alone does not satisfy case reporting, labs keep reports for two years and keep positive materials at least one week (DPH disease reporting).
- Biomedical waste. EPD Rule 391-3-4-.15 applies to labs; generators of 100 lb or more per month must meet the full rule, smaller generators a partial set of requirements.
- Quality system. 42 CFR Part 493 — personnel, QC, IQCP, proficiency testing, and the quality system; accreditation through CAP, COLA, TJC, AABB, or ACHC where applicable.
Frequently asked questions
Does Georgia require a state clinical laboratory license?
No. Since July 1, 2021, House Bill 93 removed Georgia state licensure for clinical laboratories, collection stations, tissue banks, and laboratory directors, and DCH suspended enforcement of Rule 111-8-10. Labs still need the correct federal CLIA certificate.
What is included in a mock inspection?
Document review and a walk-through against the CLIA, CAP, or COLA checklist, followed by a written findings report and corrective-action plan.
Work with a Georgia clinical lab consultant
Sound Lab Consultants is headquartered at 25 Arizona Pl, Chandler, AZ 85225 and works with Georgia clinical laboratories remotely and on-site. We are an independent consulting firm with no affiliation to any state agency, CMS, CDC, FDA, CAP, COLA, or The Joint Commission.
Book a free consultationLast reviewed: November 2026. Rules cited from official Georgia and federal sources; confirm current versions before filing.